2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our corporation insists all along the quality policy of "product top quality is base of organization survival; purchaser pleasure will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" plus the consistent purpose of "reputation very first, purchaser first" for Liquid Nitrogen Spray , Lng , Cryo Dewar , Quality is factory's lifestyle , Focus on customers' demand could be the source of corporation survival and advancement, We adhere to honesty and great faith operating attitude, looking ahead on your coming !
2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy Detail:

Product Application

The product series of Vacuum Valve, Vacuum Pipe, Vacuum Hose and Phase Separator in HL Cryogenic Equipment Company, which passed through a series of extremely strict technical treatments, are used for transferring of liquid oxygen, liquid nitrogen, liquid argon, liquid hydrogen, liquid helium, LEG and LNG, and these products are serviced for cryogenic equipment (e.g. cryogenic tanks, dewars and coldboxes etc.) in industries of air separation, gases, aviation, electronics, superconductor, chips, pharmacy, biobank, food & beverage, automation assembly, chemical engineering, iron & steel, and scientific research etc.

Vacuum Insulated Shut-off Valve

The Vacuum Insulated Shut-off / Stop Valve, namely Vacuum Jacketed Shut-off Valve, is the most widely used for VI valve series in the VI Piping and VI Hose System. It is responsible for controlling the opening and closing of main and branch pipelines. Cooperate with other products of the VI valve series to achieve more functions.

In the vacuum jacketed piping system, the most cold loss is from the cryogenic valve on the pipeline. Because there is no vacuum insulation but conventional insulation, the cold loss capacity of a cryogenic valve is far more than that of a vacuum jacketed piping of dozens of meters. So there are often customers who chose the vacuum jacketed piping, but the cryogenic valves on both ends of the pipeline choose the conventional insulation, which still leads to huge cold losses.

The VI Shut-off Valve, simply speaking, is put a vacuum jacket on the cryogenic valve, and with its ingenious structure it achieves the minimum cold loss. In the manufacturing plant, VI Shut-off Valve and VI Pipe or Hose are prefabricated into one pipeline, and there is no need for installation and insulated treatment on site. For maintenance, the seal unit of VI Shut-off Valve can be replaced easily without damaging its vacuum chamber.

The VI Shut-off Valve has a variety of connectors and couplings to meet different situations. At the same time, the connector and coupling can be customized according to customer requirements.

HL accepts the cryogenic valve brand designated by customers, and then makes vacuum insulated valves by HL. Some brands and models of valves may not be able to be made into vacuum insulated valves.

About VI valve series more detailed and personalized questions, please contact HL cryogenic equipment directly, we will serve you wholeheartedly!

Parameter Information

Model HLVS000 Series
Name Vacuum Insulated Shut-off Valve
Nominal Diameter DN15 ~ DN150 (1/2″ ~ 6″)
Design Pressure ≤40bar (4.0MPa)
Design Temperature -196℃~ 60℃ (LH2 & LHe:-270℃ ~ 60℃)
Medium LN2, LOX, LAr, LHe, LH2, LNG
Material Stainless Steel 304
On-site Installation No
On-site Insulated Treatment No

HLVS000 Series, 000 represents the nominal diameter, such as 025 is DN25 1″ and 100 is DN100 4″.


Product detail pictures:

2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy detail pictures

2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy detail pictures

2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy detail pictures

2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy detail pictures


Related Product Guide:

Assume full responsibility to satisfy all needs of our clients; achieve continual advancements by endorsing the expansion of our purchasers; turn into the final permanent cooperative partner of clientele and maximize the interests of clients for 2021 Good Quality Liquefied Natural Gas - Vacuum Insulated Shut-off Valve – Holy , The product will supply to all over the world, such as: Bahamas, Egypt, Niger, Our tenet is "integrity first, quality best". We have confidence in providing you with excellent service and ideal products. We sincerely hope we can establish win-win business cooperation with you in the future!
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Erin from Zambia - 2017.09.28 18:29
    The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Jill from Portland - 2017.01.28 19:59